Orange L929 cells on a light blue background.

Cell Morphology Assay

Your non-invasive and high-content live cell morphology assay

HoloMonitor cell morphology assay icon

The label-free HoloMonitor® Cell Morphology Assay enables non-invasive live cell imaging and kinetic analysis of a wide range of morphological properties, including individual cell volume, area, and thickness. With the add-on fluorescence unit, you can add a green fluorescence dimension to the holography data, providing enhanced insights into your cell cultures.

Time-lapse video showing the dynamic of living cells, captured with HoloMonitor.

Benefits

Why choose the HoloMonitor Cell Morphology Assay?

High-content

Study 30+ cell morphology features for every single cell in your population, plus extract proliferation & motility data.

Learn more…

Accurate

Get exact cell segmentation with digital holography to measure what you actually want to study.

Learn more…

Versatile

Detect early drug responses from cell morphology changes, study the cell cycle, analyze cell death kinetics or classify sub-populations. Applications are endless!

Learn more…

Continuous

Monitor cellular processes, cell behavior, and characteristics in real-time with a high temporal resolution. And as a result, you won’t miss any critical cellular events.

Learn more…

HoloMonitor cell morphology assay icon HoloMonitor Cell Morphology Assay

€3,200

This is a software license valid for installation on 2 PCs. Additional licenses can be purchased at 50% of the original cost. The hardware is sold separately.

Assay Output

The HoloMonitor Cell Morphology Assay measures a wide range of morphological properties of individual cells, including cell volume, area, and thickness. The optional fluorescence dimension enables the integration of green fluorescence data into the label-free holography results.

Scatter plots help visualize differences between control and treated cells. And they assist you in comparing cellular characteristics at different time points of the experiment.

Gating regions enable you to classify sub-populations and identify (rare) cells of interest. In addition, you could add HoloMonitor Single Cell Tracking for further single-cell analysis.

Moreover, histograms show the cell population distribution of selected morphological parameters at selected time points.

Some cell morphology assay parameters

What results do you get with the HoloMonitor Kinetic Cell Morphology Assay?

  • 30+ cell morphology features with the possibility for fluorescence
  • Calculation spreadsheets of all data, including population averages
  • Images and time-lapse videos of kinetic morphology changes
Scatter plots with gating functionality make it easy for you to visualize your kinetic cell morphology data.
Live cell imaging allows for studying cellular events, such as cell division, with high temporal resolution.
3D zoomed-in image of two individual cells. The cells are not stained in any way. In fact, the colors are added in the software.
The add-on fluorescence unit makes it possible to add a green fluorescence dimension to the label-free holography data and study your cells’ behavior in more detail.

High-content.

Numerous results from one sample on single-cell level

Usually, we think of cell morphology as cell area, cell volume, and maybe cell shape. However, using HoloMonitor, you can analyze more than 30 different cell morphology features over time. Above all, many of those parameters are unique for our non-invasive digital holography technology. Now, this provides you with in-depth data on every single cell in your population. Furthermore, you can gain further results from the same sample by combining this assay with other HoloMonitor live cell assays or the add-on fluorescence unit. For example, you can extract cell proliferation and cell motility data for a more detailed picture.

To the top

Same cell – many shapes!

Primary cell with varying morphology imaged with HoloMonitor.
A detailed 3D holographic image of a primary cell with varying morphology, captured with HoloMonitor.

Accurate.

Exact cell segmentation makes live cell identification simple

Firstly, individual living cells are much more easily singled out from the background with quantitative phase imaging in comparison to traditional methods, such as phase contrast. As a result, robust computer algorithms can automatically and precisely quantify cell morphology changes down to every single cell in your population. This way, you receive exact cell morphology assay results. And measure what you actually want to study.

To the top

On-demand Webinar

Watch our expert cell morphology webinar!

Join our PHI CSO, Kersti Alm, when she highlights the great potential of quantifying cell morphology, for both single-cell and cell populations.

Key Applications

What can you study with the HoloMonitor Cell Morphology Assay?

Cell life dynamics

Cell culture health & quality

Drug response & early drug effects

Cytotoxicity & cell death

Epithelial–mesenchymal transition (EMT)

Cell differentiation

Cell (state) classifications

Sub-population studies

Cell cycle studies

Cell division

Co-culture

Report gene expression

Uptake assay

Transfection efficiency

Versatile.

Kinetic cell morphology is in the focus of many applications

Many naturally occurring cell processes, such as cell division, cell density, and cell movement affect cell morphology. Also, combining cell morphology assay results with cell proliferation, and cell motility is a powerful tool. Not only, for example, for cytotoxicity studies or in vitro drug development.

Not only can you detect early drug responses from cell morphology changes. But also study the cell cycle, analyze cell death kinetics, or classify subpopulations.

Individual cell morphology insights are useful for:

  • For evaluation of cell culture health and quality
  • As early and sensitive markers to detect drug effects
  • To provide information on drug mode of action
  • For identification of dying cells

To the top

Cell Morphology Assay Protocol

How do you set up this in kinetic cell morphology assay?

Hand placing 24-well HoloLid on 24-well microplate

1. Sample preparation

  • Prepare your cell cultures in your standard vessel as you normally would.
  • Use HoloLids for optimal image quality and data acquisition.
  • Click your cell culture vessel onto the HoloMonitor motorized stage and you are ready to go!
cell morphology assay setup

2. Assay setup

  • Select the Cell Morphology Assay in the software and follow the guided workflow. Next, name your experiment and define treatments.
  • Add the positions you want to image. Also, choose how often and for how long you want to image your cells.
  • Start imaging and walk away!

3. Explore results

  • Receive kinetic gap closure data and time-lapse videos in real-time. Analyze the results with other live cell assays for deeper insights into your cells.
  • Export the raw data to Excel for further analysis and customized data presentation.
  • Re-use the untouched cells for other experiments!

Continuous.

Never miss an important cellular event

HoloMonitor is designed to operate 24/7 directly inside your standard incubator. This makes it possible for you to continuously monitor and quantify your cell cultures in their undisturbed environment. The high temporal resolution of the system allows you to study in-depth cellular processes, cell behavior, and changing cell morphology characteristics in real-time without missing any important cellular events in your culture.

To the top

A panel of cellular parameters, including cell morphology, proliferation, and motility, were quantitatively measured and analyzed using [HoloMonitor]. This novel and quantitative approach provides the opportunity to continuously and non-invasively study relevant cellular processes, behaviors, and characteristics of cancer cells and other cell types in a simple and integrated manner.

Jing Huang et al.
A Time-lapse, Label-free, Quantitative Phase Imaging Study of Dormant and Active Human Cancer Cells, Journal of Visualized Experiments (2018)

Browse our publication library for more references and see how our worldwide HoloMonitor users run their kinetic cell morphology analysis.

BCAP31, a cancer/testis antigen-like protein, can act as a probe for non-small-cell lung cancer metastasis

Authors: Jing Wang et al.

Journal: Scientific Reports (2020)

Research Areas: Cancer research

Cell Lines: A549, PLA-801D, GLC-82

Keywords: HoloMonitor M4, cell morphology and cell movements

Learn more …

Berberine Maintains the Neutrophil N1 Phenotype to Reverse Cancer Cell Resistance to Doxorubicin

Authors: Shuhui Zhang et al.

Journal: Frontiers in Pharmacology (2020)

Research Areas: Pharmacology

Cell Lines: HL-60

Keywords: HoloMonitor M4, cell morphology and cell movements, berberine, doxorubicin, neutrophil phenotype, carcinogenesis, chemotherapeutic resistance

Learn more …

Evaluation of the Impact of Imprinted Polymer Particles on Morphology and Motility of Breast Cancer Cells by Using Digital Holographic Cytometry

Authors: Megha Patel et al.

Journal: Applied Sciences (2020)

Research Areas: Cancer research, Materials of Science

Cell Lines: MCF-7 and MDAMB231

Keywords: HoloMonitor M4, Cell morphology and cell movements, breast cancer, digital holographic cytometry, molecularly imprinted polymers, motility, sialic acid, viability

Learn more …

Synthesis and biological evaluation of 4,5,6,7‐tetrahydrothieno[2,3‐c]pyridine–based β‐aminonitriles and their derivatives: β‐amino carboxamides, (thio)ureas, and tetracycles

Authors: Ramóna Madácsi et al.

Journal: Journal of Heterocyclic Chemistry (2019)

Research Areas: Drug reseach

Cell Lines: A549

Keywords: HoloMonitor M3, Cell morphology

Learn more …
1121314151636