Kinetic Cell Motility Assay

Your automated and non-invasive kinetic cell motility assay

HoloMonitor cell motility assay icon

The HoloMonitor® Kinetic Cell Motility Assay is designed to explore the average motility of cells in a population and is ideal for studies investigating how various treatments, drug candidates, or environments, influence cell movement over time. Analyze long-term cellular movement in real-time right inside your standard incubator.

24h quantitative time-lapse video showing the dynamic of living cells, captured with HoloMonitor.

Benefits

Why choose the HoloMonitor Kinetic Cell Motility Assay?

Kinetic

Collect data automatically throughout the whole experiment — no more watching the clock to take time points.

Learn more…

Automatic

Receive immediate real-time data and image sequences while the experiment is still running.

Learn more…

Single-cell based

Trust the direct measurement of individual cells for your cell population motility results, thanks to QPI technology.

Learn more…

Non-invasive

Avoid cell behavior influences and toxins from cellular labels. Also, re-use your untouched cells for further experiments.

Learn more…

HoloMonitor cell motility assay icon HoloMonitor Kinetic Cell Motility Assay

€3,060

This is a software license valid for installation on 2 PCs. Additional licenses can be purchased at 50% of the original cost. The hardware is sold separately.

Assay Output

What results do you get with this Kinetic Cell Motility Assay?

The HoloMonitor Kinetic Cell Motility Assay measures the motility of a cell population over time.
This assay calculates and presents in real-time kinetic motility data of the mean speed of all cells in a population over time. In addition, you receive the accumulated mean distance at each time point.

  • Mean cell speed [µm/h]
  • Accumulated mean cell distance [µm]
  • Cell images and time-lapse videos
  • Combine with the Single Cell Tracking Assay for in-depth individual cell data

App Suite software automatically presents the imaging data in real-time as well as in an organized way.

HoloMonitor imaging time-lapse of stem cells on microgrid arrays.

Kinetic graph of the mean cell speed [µm/h] measured for three different types of macrophages.
The accumulated mean cell distance at each time point is automatically determined by the software.

Single-cell based.

Get directly-measured cell population data

Compared to traditional phase contrast microscopy, the quantitative phase imaging (QPI) technology used by HoloMonitor offers exceptional automatic cell segmentation and identification no matter your cells’ shapes and sizes. This enables the software to robustly follow the movement behavior of every cell in the population over time, in real-time.

To the top

Grey tracked cell on black background with a green line showing its path

Do you further want to study kinetic motility on a single-cell level?

Automatic.

Save hours of hands-on lab time

The guided kinetic cell motility assay workflow not only reduces your hands-on lab time but also contributes to increasing your experiment reproducibility. Certainly, there is no need to supervise the imaging process with this walk-away assay. In fact, the HoloMonitor system automatically captures multi-well time-lapses with a high temporal resolution however long you would like to run your assay for. Also, the software automatically presents your population motility data while the experiment is still running.

In addition, the motility assay results can easily be re-analyzed with other HoloMonitor live cell assays to generate multiple results, such as proliferation data, and deeper insights — all from the same cell sample and without running further experiments.

To the top

On-demand Webinar

Watch our cell motility & cell migration webinar!

Find out how you can quantify cell movements using non-invasive live cell imaging and relate them to other cellular parameters, such as cell size and shape.

Key Applications

What can you study with the HoloMonitor Kinetic Cell Motility Assay?

Cell motility & Cell migration

Drug treatment effects

Cell Motility Assay Protocol

How do you set up this in kinetic cell motility assay?

Pipetting with Hololid in 6-well microplate

1. Sample preparation

  • Prepare your cell with your standard vessel and media as you normally would.
  • Use HoloLids for optimal image quality and data acquisition.
  • Click your cell culture vessel onto the HoloMonitor motorized stage and you are ready to go!
HoloMonitor kinetic cell motility assay software setup

2. Assay setup

  • Select the Kinetic Cell Motility Assay in the software and follow the guided workflow. Next, name your experiment and define treatments.
  • Add the positions you want to image. Also, choose how often and for how long you want to image your cells.
  • Start imaging and walk away!
HoloMonitor kinetic motility assay output software screenshot

3. Explore results

  • Receive real-time mean cell population motility data and time-lapse videos. Analyze the results with other live cell assays for added insights.
  • Export the raw data to Excel for further analysis and customized data presentation.
  • Re-use your untouched cells for other experiments!

Kinetic.

We all know about the importance of time

HoloMonitor is a live cell analysis tool designed for and by cell biologists. So, we made sure that everything from assay setup, to imaging and data presentation, is making your daily lab routine easier. Therefore, your cells’ motility data is collected automatically throughout the whole experiment — no more watching the clock to tediously take time points yourself. Also, in comparison to taking only a few data points manually, this kinetic motility assay is providing you with multi-well data down to every minute, if you need it. As a result, you receive detailed real-time insights into how, for example, a drug treatment influences your cells’ motility behavior.

To the top

Cell Motility — An Alternative to the Transwell Assay

In Evaluation of Holographic Imaging Cytometer HoloMonitor M4 Motility Applications, Cytometry Part A (2018), Zhang et al. have shown that the average cell motility provides similar cell migration results as obtained by wound healing and transwell assays.

Cell motility is quantified by measuring the non-directional movement of cells in a standard cell culture sample. This makes it possible to quantify in vitro cell migration and cell proliferation simultaneously, without requiring cell starvation or special sample preparation, nor does it require any labels.

These findings were applied in Bi-allelic Loss of CDKN2A Initiates Melanoma Invasion via BRN2 Activation, Cell Cancer (2018).

Non-invasive.

Create relevant assay conditions for relevant answers

By imaging right inside your standard incubator, HoloMonitor creates a stable and relevant assay environment for your cells. In addition, using this non-invasive motility assay does not only reduce the risk of unwanted toxicity. This assay also allows cell samples to be reused, as no reagents are added to the sample. Hence, they save time and money. But foremost non-invasive assays save hard-to-get cells. This way, the HoloMonitor Kinetic Cell Motility Assay is ideal for long-term studies of your live cell cultures.

To the top

Indeed, this technique has been demonstrated to accurately measure cell growth, cell motility and migration, cell death, cell cycle, and drug responses in a wide variety of cell lines in the laboratory and in the clinical setting.

Laura V. Croft et al.
Digital Holographic Imaging as a Method for Quantitative, Live Cell Imaging of Drug Response to Novel Targeted Cancer Therapies (2019)

Browse our publication library for more references and see how our worldwide HoloMonitor users run their kinetic cell motility analysis.

The Toxic Effect of Water-Soluble Particulate Pollutants from Biomass Burning on Alveolar Lung Cells

Authors: Yuri Lima de Albuquerque et al.

Journal: Atmosphere (2021)

Research Areas: Cell research

Cell Lines: A549 cell

Keywords: HoloMonitor M4, cell proliferation and viability, cell motility, wood biomass burning particles, in vitro cytotoxicity, rtca

Learn more …

Mast cell tryptase enhances wound healing by promoting migration in human bronchial epithelial cells

Authors: Sofia Mogren et al.

Journal: Cell Adhesion & Migration (2021)

Research Areas: Cell research

Cell Lines: BEAS-2B

Keywords: HoloMonitor M4, cell migration, single cell tracking, wound healing, cell morphology, mast cell, tryptase, epithelial cells, protease activated receptor 2

Learn more …

Breast cancer cell line toxicity of a flavonoid isolated from Baccharis densiflora

Authors: Wendy Soria Sotillo et al.

Journal: BMC Complementary Medicine and Therapies (2021)

Research Areas: Cancer research

Cell Lines: JIMT-1

Keywords: HoloMonitor M4, Cell motility, Cell proliferation, Flavonoids, Sideritoflavone, Breast cancer, Cytotoxicity, Cell cycle, Cell movement, Cancer stem cells

Learn more …

The anti-tumor efficacy of 20(S)-protopanaxadiol, an active metabolite of ginseng, according to fasting on hepatocellular carcinoma

Authors: Wenzhen Li et al.

Journal: Journal of Ginseng Research (2021)

Research Areas: Cancer research

Cell Lines: HepG2, H22

Keywords: HoloMonitor M4, cell proliferation, single cell track, 20(S)-protopanaxadiolfasting-mimickingintermittent fasting, hepatocellular carcinoma

Learn more …
15678923